The packets the Bloodhound sends out to WITS, in order, are:
0140 –Total Gas (if Register 12 is not zero). The Total Gas value sent is divided by the number in Register 26.
1212 – C1 (if Register 68 is 0, sent as Gas Units. If Register 68 is 1, sent as parts per million (PPM).
1213 – C2 (if Register 68 is 0, sent as Gas Units. If Register 68 is 1, sent as parts per million (PPM).
1214 – C3 (if Register 68 is 0, sent as Gas Units. If Register 68 is 1, sent as parts per million (PPM).
1215 – iC4 (if Register 68 is 0, sent as Gas Units. If Register 68 is 1, sent as parts per million (PPM).
1216 – nC4 (if Register 68 is 0, sent as Gas Units. If Register 68 is 1, sent as parts per million (PPM).
1217 – iC5 (if Register 68 is 0, sent as Gas Units. If Register 68 is 1, sent as parts per million (PPM).
1218 – nC5 (if Register 68 is 0, sent as Gas Units. If Register 68 is 1, sent as parts per million (PPM).
1222 – CO2
1225 – O2
0141 – H2S
0139 – Lag Calc